Solar flat plate collectors are normally installed in conservation Areas, sites of outstanding beauty and the like, but can also be installed in many different configurations which will make it more pleasing to the eye.

Allbrite UK Ltd offer the high efficiency compact range and premium range from Schüco and Kingspans Thermomax range.
The panels used will sometimes be dictated by the type of solar installation required, all panels are suitable for on-roof solar installation and in-roof solar installation, however if you require a facade, canopy or whole roof installation we would tend to offer the Schüco range of panels and solar fixing sundries.
Compact Line Flat Plate Collector Data
| Dimensions | 2039 x 1139 x 80 mm |
| Panel Area | 2.32 m2 |
| Absorber Area | 2.15 m2 |
| Efficiency | 79.9% |
| Nominal Thermal Output | 1.7 kW |
Premium Line Flat Plate Collector Data
| Dimensions | 2152 x 1252 x 93 mm |
| Panel Area | 2.69 m2 |
| Absorber Area | 2.52 m2 |
| Efficiency | 80.8% |
| Nominal Thermal Output | 2.0 kW |
Thermomax Solar Flat Plate Technical data
Aperture Area |
1.969m2 |
Absorber Area |
2.0075m2 |
Overall Dimensions |
1870 x 1150 x 95mm |
Fluid Volume |
1.70 Ltr |
Inlet and Outlet Dimensions |
22mm compression or Ø22mm plug-system with double-O-ring |
Weight (Empty) |
35kg |
Recommended Inclination |
20-90° |
Hydraulic Connection |
Parallel connection with collectors side-by-side |
Efficiency |
Based on aperture |
eta 0 |
0.775 |
k1 |
3.73 W/m2K |
k2 |
0.0152 W/m2K2 |
Flow Rate |
|
Rated |
120 Ltr / h |
Minimum |
50 Ltr / h |
Maximum |
120 Ltr / h per collector, per field up to 700 Ltr / h |
Maximum Operating Pressure |
10 Bar |
Stagnation Temperature |
217°C |
Heat Transfer Fluid Water/Glycol |
Antifreeze mix based on propylene-glycol |
Collector Case |
Aluminium frame, powder coated |
Insulation |
50mm mineral wool |
Absorber |
Cu-sheet and Cu-tubes, laser welded |
Coating |
Highly selective on copper |
Absorbance |
95% |
Emissivity |
5% |
Absorber Type |
Absorber with 1 serpentine Ø9mm and 2 manifolds Ø22mm |
Mounting Frame and Clips |
Stainless steel, aluminium |
Glass |
Low iron, structured, solar safety glass (ESG) - Transm. 0.915 |
Impact Resistance of Covering |
EN12975-2. passed optional impact resistance tests |
Permissible Wind and |
3 kN/m2 suction, |
Snow Load |
5 kN/m2 pressure |
Warranty |
5 year functionality and weathering resistance warranty 10 year warranty with certified installation |
Quality Certification |
Solar Keymark |